Recyfix Channel Drainage: Hydraulic Performance Explained

Recyfix channel drainage combines lightweight polypropylene channel bodies with efficient internal geometry designed to collect, retain and convey surface water.

One important design consideration is whether a drainage run needs a built-in fall. In many applications, a constant-depth Recyfix channel can provide the required hydraulic performance without an internal gradient – provided the complete system is correctly sized for the catchment area, rainfall and outlet conditions.

Does channel drainage need a built-in fall?

Not always.

Channel drainage systems can use a constant depth, stepped sections or a built-in internal fall. A built-in gradient can increase water velocity, but it also reduces the available channel cross-section towards the shallower end of the run.

A constant-depth channel maintains its full internal cross-section throughout the drainage line. This can provide additional storage and conveyance capacity during heavy rainfall.

Hydraulic calculations published for Recyfix systems show that, in the analysed configuration, a constant-depth channel achieved comparable end-of-run flow velocity while providing additional hydraulic volume.

The correct solution should always be verified for the individual project rather than assuming that one configuration is suitable for every application.

What affects channel drainage performance?

Design factorWhy it matters
Catchment areaDetermines how much surface water reaches the channel
Rainfall intensityInfluences the peak flow the system must manage
Channel cross-sectionControls conveyance and temporary storage capacity
Run lengthAffects water depth and flow through the system
Outlet positionDetermines where collected water can leave the channel
Downstream capacityLimits how much water the complete system can discharge

This is why hydraulic design should be completed before selecting channel size or assuming that a built-in fall is required.

Galco’s hydraulic calculation tools can be used to assess channel configuration, flow rates and drainage requirements for a specific project.

Why use RECYFIX channels?

Recyfix systems use modified polypropylene channel bodies, allowing relatively slim wall construction and therefore a larger internal drainage cross-section within a compact external size.

The lower unit weight also makes many Recyfix systems easier to transport and position than heavier mineral-based channels. Different ranges are available for applications from pedestrian and landscaped areas through to heavily trafficked industrial environments.

Depending on the project, options include:

  • RECYFIX STANDARD for general drainage applications;
  • RECYFIX PRO for public and commercial areas;
  • RECYFIX NC for trafficked and industrial environments;
  • RECYFIX MONOTEC for high-capacity monolithic drainage;
  • RECYFIX HICAP for large areas with demanding hydraulic requirements.

RECYFIX HICAP systems, for example, combine drainage and retention capacity and are available for demanding applications up to F900.

recyfix channel drainage

Constant-depth or built-in-fall drainage?

Neither option is automatically better.

Constant-depth channels can maximise the available drainage cross-section and simplify the use of repeated channel sections.

Built-in-fall channels create a gradual internal gradient towards the outlet and may be useful where the hydraulic design or site conditions favour this arrangement.

The choice should be based on hydraulic calculation, available installation depth, channel length and outlet position rather than the assumption that water will only flow effectively in a pre-sloped channel.

For a broader comparison, see our guide to the types of channel drainage systems.

Summary

Recyfix channel drainage does not automatically require a built-in fall to provide effective surface water drainage.

Constant-depth channels can maintain a larger internal cross-section throughout the run, providing conveyance and temporary storage capacity. However, the correct configuration must always be determined from the actual catchment area, rainfall, channel length and outlet conditions.

Use Galco’s hydraulic design service or contact the drainage team to identify the right Recyfix system for your project.

Frequently asked questions

Do RECYFIX channels need a built-in fall?

Not necessarily. Constant-depth Recyfix channels can provide effective drainage where the channel size, outlet arrangement and hydraulic design are suitable.

How does water flow in a level drainage channel?

Water depth increases progressively as runoff enters the channel, creating hydraulic head that drives flow towards the outlet. A built-in physical slope is therefore not always necessary.

Does a larger channel always provide better drainage?

No. The channel needs to be sized for the catchment, rainfall, run length and outlet capacity. Oversizing can increase cost and installation depth without providing a practical benefit.

Which RECYFIX system is suitable for heavy-duty areas?

The appropriate system depends on both load and hydraulic requirements. Recyfix NC, MONOTEC, MONOTEC ULTRA and HICAP ranges include options for demanding trafficked environments.

 

Reviewed by Galco Drainage Technical Team
Last updated: August 2026